FIREFRAMES

HEAT BARRIER SERIES DOORS

QUOTE||800.426.0279
frames-logo-FFHB

Fire-Rated Doors

FIRE RATING 60/90 MINUTES

FAQ
Answers

Compare
Products

Fireframes® Heat Barrier Series die-rolled steel profile doors, combined with Pilkington Pyrostop® fire-rated glass, provide a barrier to radiant and conductive heat transfer allowing for full-lite, fire-rated doors. A sleek alternative to typical hollow metal doors, Fireframes Heat Barrier Series doors feature precise edges, professional finish, and the narrowest sightlines available with a fire rating. Pre-hung, pre-finished and easy to install, Fireframes Heat Barrier Series doors complement adjacent non-fire-rated doors allowing for continuity in your designs.

“We specified a product that also allowed us to install the largest size of glass we could get with minimal framing.”

-David Steele, Muller and Muller

KEY FEATURES


  • Fire ratings of 60-90 minutes with required hose stream test
  • Narrow steel profiles provide a seamless aesthetic with adjacent non-fire-rated aluminum doors in a given project
  • Durable welded steel construction of doors ensure low maintenance system
  • Pre-hung, prefinished, with door hardware included (contact TGP regarding your individual hardware requirements)
  • Full-lite doors available in single leaf or double leaf design
  • For applications other than doors, see Fireframes Heat Barrier Series fact sheet
  • Door hardware available to fit functional requirements. Check with TGP for compatibility
  • Finish powder coating at the factory to match desired color scheme
  • Can be easily integrated into Fireframes storefront and framing systems
  • Installs into a finished opening
  • Can incorporate large individual panes of Pilkington Pyrostop® fire-resistive-rated glass, comprised of Pilkington Optiwhite glass and clear intumescent layers

ATTRIBUTES



MAXIMUM SIZE

Maximum Allowable Size Information



DOORS

Doors: Singles and AA Rating Max. Width Max. Height
Max. Door Leaf Size 60/90 min. 49-1/4" 112-7/16"
Max. Door Opening Active-Active (AA Pair) 60/90 min. 98-1/8" 112-7/16"

Note: For double egress, please reference Architectural Specification Manual

HARDWARE

All door hardware for Fireframes Heat Barrier Series doors is supplied by Technical Glass Products. Please contact Technical Glass regarding your individual hardware requirements.

Standard door hardware package may include:

LISTINGS

Classified and labeled by Underwriters Laboratories, Inc.® and Underwriters Laboratories of Canada. File number R19207. Tests performed in accordance with:

UL 10B UL 10C
NFPA 252
CAN/ULC-S104
MEA 240-00-M LARR 25798

Design Ideas


Fireframes® Door Advantage

Use our interactive Door Design Tool for more information on the advantages of working with Fireframes® Designer Series and Fireframes Heat Barrier Series fire-rated glass doors. Click the hotspots for insights into the features and benefits of TGP’s fire-rated glass door systems.

See Door Design Tool

The time, in minutes or hours, that materials or assemblies can be expected to prevent flames and smoke from spreading.

As heat develops within the source area, pressure within the enclosed room begins to build relative to the pressure outside. Once the fire reaches equilibrium in the positive pressure zone, smoke, hot gases and flames are forced through any openings in the door or window assembly. Testing to the UL 10C standard more closely simulates real fire conditions.

Blocks radiant and conductive heat transfer from one side of the glass to the other. A required characteristic of glass used as a wall.

Classified and labeled by Underwriters Laboratories, Inc.® (UL), an independent product safety certification organization.

Immediately following a furnace test, heated glass is subjected to water from a fire hose. The cooling, impact and erosion created by the hose stream tests the integrity of the glass. In the U.S., the hose stream test is required for all fire ratings over 45 minutes (all fire ratings require it in Canada).

Available as a temperature rise door with Pilkington Pyrostop® fire-resistive-rated glass for 60-90 minute applications

Temperature rise doors provide a barrier to radiant and conductive heat transfer.

Available in stainless steel frame finish options for increased design flexibility.

Building codes clearly define hazardous locations where impact safety glass is required. Glass with this designation has been tested to meet impact safety requirements required for areas such as doors, sidelights, and areas close to the floor.

FireLite IGU is a fire-rated insulated glass ceramic unit that also complies with energy codes. It is designed for use in exterior applications where energy codes require an insulated product, or for interior applications with special needs such as sound reduction.

Withstands continuous temperatures to 1292° F for use in high efficiency heating appliances.

The ability of glass ceramic to withstand sudden heating, cooling, or both without cracking, shattering or exploding out of the frame.

The ability of the glass to stop various types of ammunition. Ratings are assigned in levels from 1 to 8, with a Level 8 rating being the highest (able to stop a 7.62mm rifle lead core full metal copper jacket, military ball).

The capacity of an element in a building structure to support a weight in addition to its own.

Listed and labeled by Intertek, an independent assurance, testing, inspection and certification organization.

Glazing designed to increase the amount of time required to gain entry. This additional time is intended to allow for the enactment of lock-down protocols and to allow for the arrival of emergency response teams. May be used in areas with high risk of prolonged attack or in critical areas such as vestibules. Forced entry resistant glazing should also resist penetration from hand-held or hand-thrown objects such as hammers, crowbars, bats, knives, bricks and rocks. (Source: NGA Glass Technical Paper FB71-21)

This product is both fire- and security-rated and is appropriate for educational facilities.

This product is smoke-rated and tested to UL 1784.

Sign up for TGP's Newsletter

Send me emails about product info, continuing education opportunities and other news from Technical Glass Products

Click here to dismiss this window.

By clicking submit, you agree to this web site’s terms of use. To unsubscribe from receiving emails from Technical Glass Products, click the Unsubscribe link at the bottom of our emails or contact Allegion at dataprivacy@allegion.com. You understand and agree that your information may be transferred into the United States or other locations outside your country of residence. For more information on our privacy practices, please see our Privacy Policy.